C40 Charge Controller
Product Description
Electrical Specifications:
* Voltage Configurations: 12,24 and 48 VDC
* Max. PC Open Circuit Array Voltage: 125 VDC
* Charging / Load Current (at 25 °C): 40 amps DC
* Max. Peak Current: 85 amps
* Max Voltage Drop through Controller: 0.30 volts
* Typical Operating Consumption: 15 ma
* Typical Idle COnsumption: 3ma
* Recommended Breaker Size: 50 amps
* Recommended Wire Size: #8 AWG
* Lead Acid Battery Settings: Adjustable
* NiCad Battery Settings: Adjustable
* Load Control Mode: Low Voltage Reconnect - Adjustable (sticker provided with unit) all models
Low Voltage Disconnect - User selectable manual or automatic reconnection - includes warning flash before disconnect and provides a one time, user selectable grace period) all models
General Specifications
* Specified Temperature Range: 32 F to 104 F (0 C to 40 C)
* Enclosure Type:Indoor, ventilate, powder coated steel with 3/4" and 1" knockouts
* Unit Weight3.0 lb (1.4 kg)
* Shipping Weight 3.5 lb(1.6 kg)
* Dimensions(H x W x D): 10 x 5.0 x 2.5"
* Shipping Dimenson(H x W X D): 12.4 x 7 x 2.5"
* Mounting: Vetical wall mount - indoor only
* Altitude-Operating 15,000' (4,572 m)
* Altitude-Non-Operating50000' (15,240 m)
* Warranty:2 years
Features and Options:
* Regulation Method: Solid stage, three-stage (bulk,absorption,and float), pulse width modulation
* Field Adjustable Control Setpoints:Two user adjustable voltage setpoints for control of loads or charging sources - setting retained if battery is disconnected
* Equalization Charge: User selectable manal or automatic equalization - every 30 days
* Battery Temperature Sensor:BTS - optional remote battery temperature sensor for increased charging precision
* Voltage Configurations: 12,24 and 48 VDC
* Max. PC Open Circuit Array Voltage: 125 VDC
* Charging / Load Current (at 25 °C): 40 amps DC
* Max. Peak Current: 85 amps
* Max Voltage Drop through Controller: 0.30 volts
* Typical Operating Consumption: 15 ma
* Typical Idle COnsumption: 3ma
* Recommended Breaker Size: 50 amps
* Recommended Wire Size: #8 AWG
* Lead Acid Battery Settings: Adjustable
* NiCad Battery Settings: Adjustable
* Load Control Mode: Low Voltage Reconnect - Adjustable (sticker provided with unit) all models
Low Voltage Disconnect - User selectable manual or automatic reconnection - includes warning flash before disconnect and provides a one time, user selectable grace period) all models
General Specifications
* Specified Temperature Range: 32 F to 104 F (0 C to 40 C)
* Enclosure Type:Indoor, ventilate, powder coated steel with 3/4" and 1" knockouts
* Unit Weight3.0 lb (1.4 kg)
* Shipping Weight 3.5 lb(1.6 kg)
* Dimensions(H x W x D): 10 x 5.0 x 2.5"
* Shipping Dimenson(H x W X D): 12.4 x 7 x 2.5"
* Mounting: Vetical wall mount - indoor only
* Altitude-Operating 15,000' (4,572 m)
* Altitude-Non-Operating50000' (15,240 m)
* Warranty:2 years
Features and Options:
* Regulation Method: Solid stage, three-stage (bulk,absorption,and float), pulse width modulation
* Field Adjustable Control Setpoints:Two user adjustable voltage setpoints for control of loads or charging sources - setting retained if battery is disconnected
* Equalization Charge: User selectable manal or automatic equalization - every 30 days
* Battery Temperature Sensor:BTS - optional remote battery temperature sensor for increased charging precision
Product Tags
Add Your Tags:
Use spaces to separate tags. Use single quotes (') for phrases.